Alyuminiy Supero'tkazuvchilar XLPE izolyatsiyalangan sim ABC kabeli
video
Alyuminiy Supero'tkazuvchilar XLPE izolyatsiyalangan sim ABC kabeli

Alyuminiy Supero'tkazuvchilar XLPE izolyatsiyalangan sim ABC kabeli

Alyuminiy Supero'tkazuvchilar XLPE izolyatsiyalangan sim ABC kabeli
IEC standarti, ASTM, BS, NF C 33-209 standartidagi havo liniyalari (dupleks, tripleks, to'rt tomonlama) uchun ishlatiladigan ABC elektr kabeli
So'rov yuborish
Hozir chat
Ta'rif

Alyuminiy Supero'tkazuvchilar XLPE izolyatsiyalangan sim ABC kabeli

 

Biz IEC standarti, ASTM, BS, NF C 33-209 standartidagi havo liniyalari (dupleks, tripleks, to'rtlik) uchun ishlatiladigan ABC elektr kabelini ishlab chiqaramiz.

ABC cable 14 ABC cable 1 ABC cable 44


Xizmatni tushirish kabeli turi:
Xizmat ko'rsatish kabeli (ABC CABLE) asosan uchta turni qamrab oladi:
Dupleks xizmat ko'rsatishni to'xtatish
Tripleks xizmat ko'rsatishni to'xtatish
To'rt tomonlama xizmat ko'rsatishni to'xtatish
Kabel ishlab chiqarilishi mumkin, uning konstruktsiyasi neytral o'tkazgichli fazali o'tkazgich yoki izolyatsiyalangan neytral o'tkazgichli fazali o'tkazgich va hokazo. Va biz hali ham mijozlar talabiga binoan kabellarni ishlab chiqarishimiz mumkin.

Tafsiloted Service Drop Cable joriy etilishi
1 dupleks xizmat tushishi
Ilovalar: Qurilish maydonchalarida, tashqi yoki ko'cha yoritgichlarida vaqtinchalik xizmat ko'rsatish uchun 120 voltli havo xizmatini ta'minlash. Maksimal 75 o'tkazgich haroratida 600 volt yoki undan past bo'lgan xizmat uchun.

Konstruksiya: konsentrik sim yoki siqilgan 1350-H19 o‘tkazgich, polietilen yoki o‘zaro bog‘langan polietilen izolyatsiyasi, konsentrik sim AAC, ACSR yoki 6201 qotishma nertral messenjer.

2 Tripleks xizmat ko'rsatishni to'xtatish
Ilovalar: Uility's liniyalaridan iste'molchining ob-havo boshiga elektr ta'minoti uchun. 600 volt yoki undan kamroq (fazadan fazaga) xizmat ko'rsatish uchun PE izolyatsiyasi uchun maksimal 75 yoki XLPE izolyatsiyasi uchun maksimal 90 o'tkazgich haroratida.

Konstruksiya: konsentrik sim yoki siqilgan 1350-H19 o‘tkazgich, polietilen yoki o‘zaro bog‘langan polietilen izolyatsiyasi, konsentrik sim AAC, ACSR yoki 6201 qotishma nertral messenjer.

3 To'rt tomonlama xizmat ko'rsatishni to'xtatish
Ilovalar: 3 fazali quvvatni ta'minlash uchun ishlatiladi, odatda qutbga o'rnatilgan transformatordan xizmat ko'rsatish kabeliga ulanish amalga oshiriladigan xizmat ko'rsatish boshiga. 600 volt yoki undan kam fazali kuchlanishlarda va o'tkazgich haroratida pe izolyatsiya qilingan o'tkazgichlar uchun 75 dan yoki XLPE izolyatsiyalangan o'tkazgichlar uchun 90 dan oshmasligi kerak.
Konstruksiya: Supero'tkazuvchilar konsentrik torli, siqilgan 1350-H19 alyuminiy. Polietilen yoki XLPE bilan izolyatsiyalangan. Neytral messenjerlar konsentrik ravishda joylashgan 6210 AAAC, AAC yoki ACSR bilan ishlaydi.

 

Spetsifikatsiya:

Bosqich

Bosqich

Bosqich

Taxminan Umumiy diametri

Maks. DC

Supero'tkazuvchilarning qarshiligi

20 daraja haroratda

AAC va UV-XLPE

Yilni o'tkazgich

UV-XLPE izolyatsiyasi

No * Yadrolarning ko'ndalang kesimi

soni

Al simlari

Umumiy diametri

Oddiy

Qalinligi

Min.

Qalinligi

Diametri

№ X mm 2

-

mm

mm

mm

mm

mm

Om/km

1 X 10

7

4.05

1.0

0.8

6.05

6.05

3.08

1 X 16

7

4.8

1.2

0.98

7.2

7.20

1.91

1 X 25

7

6

1.2

0.98

8.4

8.40

1.20

1 X 35

7

7.0

1.4

1.16

9.8

9.80

0.868

1 X 50

7

8.3

1.4

1.16

11.1

11.10

0.641

1 X 70

19

9.8

1.4

1.16

12.6

12.60

0.443

1 X 95

19

11.6

1.6

1.34

14.8

14.80

0.320

1 X 120

19

13

1.6

1.34

16.2

16.20

0.253

1 X 150

19

14.6

1.8

1.52

18.2

18.20

0.206

1 X 185

36

16.2

2.0

1.70

20.2

20.20

0.164

1 X 240

36

18.4

2.2

1.88

22.8

22.80

0.125

2 X 10

7

4.05

1.0

0.8

6.05

12.10

3.08

2 X 16

7

4.8

1.2

0.98

7.2

14.40

1.91

2 X 25

7

6

1.2

0.98

8.4

16.80

1.20

2 X 35

7

7.0

1.4

1.16

9.8

19.60

0.868

2 X 50

7

8.3

1.4

1.16

11.1

22.20

0.641

2 X 70

19

9.8

1.4

1.16

12.6

25.20

0.443

2 X 95

19

11.6

1.6

1.34

14.8

29.60

0.320

2 X 120

19

13

1.6

1.34

16.2

32.40

0.253

2 X 150

19

14.6

1.8

1.52

18.2

36.40

0.206

2 X 185

36

16.2

2.0

1.70

20.2

40.40

0.164

2 X 240

36

18.4

2.2

1.88

22.8

45.60

0.125

3 X 10

7

4.05

1.0

0.8

6.05

13.07

3.08

3 X 16

7

4.8

1.2

0.98

7.2

15.55

1.91

3 X 25

7

6

1.2

0.98

8.4

18.14

1.20

3 X 35

7

7.0

1.4

1.16

9.8

21.17

0.868

3 X 50

7

8.3

1.4

1.16

11.1

23.98

0.641

3 X 70

19

9.8

1.4

1.16

12.6

27.22

0.443

3 X 95

19

11.6

1.6

1.34

14.8

31.97

0.320

3 X 120

19

13

1.6

1.34

16.2

34.99

0.253

3 X 150

19

14.6

1.8

1.52

18.2

39.31

0.206

3 X 185

36

16.2

2.0

1.70

20.2

43.63

0.164

3 X 240

36

18.4

2.2

1.88

22.8

49.25

0.125

4 X 10

7

4.05

1.0

0.8

6.05

14.64

3.08

4 X 16

7

4.8

1.2

0.98

7.2

17.42

1.91

4 X 25

7

6

1.2

0.98

8.4

20.33

1.20

4 X 35

7

7.0

1.4

1.16

9.8

23.72

0.868

4 X 50

7

8.3

1.4

1.16

11.1

26.86

0.641

4 X 70

19

9.8

1.4

1.16

12.6

30.49

0.443

4 X 95

19

11.6

1.6

1.34

14.8

35.82

0.320

4 X 120

19

13

1.6

1.34

16.2

39.20

0.253

4 X 150

19

14.6

1.8

1.52

18.2

44.04

0.206

4 X 185

36

16.2

2.0

1.70

20.2

48.88

0.164

4 X 240

36

18.4

2.2

1.88

22.8

55.18

0.125

 

Paket: Eksport yog'och barabanlar, havodagi abc kabeli

ABC CABLE ABC CABLE 02 ABC CABLE 03

 

Issiq teglar: alyuminiy o'tkazgich xlpe izolyatsiyalangan sim abc kabeli, Xitoy alyuminiy o'tkazgich xlpe izolyatsiyalangan sim abc kabel ishlab chiqaruvchilari, etkazib beruvchilar, zavod

So'rov yuborish

(0/10)

clearall